GENDN=0, RECLP=0, INTDEV=0, MPDUD=0, DRPTO=0, RESDN=0, INFABT=0, OFMUD=0, DRQOVR=0, INTCHG=0
SYNFP Status Register
OFMUD | offsetFromMaster Value Update Flag 0 (0): The offsetFromMaster value has not been updated. 1 (1): The offsetFromMaster value has been updated. |
INTCHG | Receive logMessageInterval Value Change Detection Flag 0 (0): No change in the received logMessageInterval value. 1 (1): A change in the received logMessageInterval value. |
MPDUD | meanPathDelay Value Update Flag 0 (0): The meanPathDelay value has not been updated. 1 (1): The meanPathDelay value has been updated. |
DRPTO | Delay_Resp/Pdelay_Resp Reception Timeout Detection Flag 0 (0): A Delay_Resp/Pdelay_Resp timeout has not occurred. 1 (1): A Delay_Resp/Pdelay_Resp timeout has occurred. |
INTDEV | Receive logMessageInterval Value Out-of-Range Flag 0 (0): The received logMessageInterval value is within the range. 1 (1): The received logMessageInterval value is out of the range. |
DRQOVR | Delay_Req Reception FIFO Overflow Detection Flag 0 (0): The received Delay_Req has not caused the reception FIFO to overflow. 1 (1): The received Delay_Req has caused the reception FIFO to overflow. |
RECLP | Loop Reception Detection Flag 0 (0): A received message has not returned through a loop. 1 (1): A received message has returned through a loop. |
INFABT | Control Information Abnormality Detection Flag 0 (0): No abnormality in control information 1 (1): Abnormality in control information |
RESDN | Response Stop Completion Detection Flag 0 (0): Stopping responses has not been completed. 1 (1): Stopping responses has been completed. |
GENDN | Generation Stop Completion Detection Flag 0 (0): Stopping generation has not been completed. 1 (1): Stopping generation has been completed. |